Vacuum Degassing Chamber

Vacuum Degassing Chamber

grabcad

For the chamber, a 325mm diameter SS pipe of 4mm thickness was used for durability against crushing. However, the 25mm acrylic glass on the cover broke due to pressure up to 30 hg. In future, it would be better to use lexan glass for improved strength.

Download Model from grabcad

With this file you will be able to print Vacuum Degassing Chamber with your 3D printer. Click on the button and save the file on your computer to work, edit or customize your design. You can also find more 3D designs for printers on Vacuum Degassing Chamber.