Vacuum Degassing Chamber
grabcad
For the chamber, a 325mm diameter SS pipe of 4mm thickness was used for durability against crushing. However, the 25mm acrylic glass on the cover broke due to pressure up to 30 hg. In future, it would be better to use lexan glass for improved strength.