CV-19 Guardian Respirator Adaptor

CV-19 Guardian Respirator Adaptor

grabcad

In response to shortages in NIOSH-approved PPE during the COVID-19 crisis, many individuals including healthcare professionals and first responders are turning to improvised masks for protection. To help provide more controlled protection under these circumstances, Dominion Engineering, Inc. (DEI) has developed a custom adaptor that can be used to convert a standard snorkel mask into a reusable, full face respirator that effectively protects the eyes, nose, and mouth from airborne particles. We have coordinated independent testing to confirm that these converted masks pass a standard mask fit test and assess the efficacy of commonly available filter insert materials. To assist individuals who may lack access to approved PPE such as N95 respirators and face shields, DEI is publishing the CV-19 Guardian Respirator Adaptor design here, along with instructions for making a converted mask using this adaptor. For additional technical information, including filter efficacy testing results for commonly available materials that can be used to make filter inserts for this adaptor, refer to the attached PDF file. Disclaimer: Improvised devices of the type discussed herein are not NIOSH-approved and the user bears all liability associated with the use of such devices. DEI is making this information available as a public service, but does not make any warranty, expressed or implied, that the use of the device described herein will protect a party from COVID-19 or any other airborne viruses. To assemble a converted respirator mask, you will need: 1. A 3D printed adaptor (design file attached) 2. A compatible snorkel mask 3. Filter insert material 4. A wide mouth lid (mason jar, or equivalent) Snorkel Mask: The CV-19 Guardian Respiratory Adaptor is designed to fit the DIVELUX snorkel mask (https://www.amazon.com/dp/B072KDWVSV/ref=cm_sw_em_r_mt_dp_U_PJ5FEbJPZE8VG). Many other commonly available snorkel masks utilize similar construction. DEI will continue to evaluate the compatibility of other masks with the CV-19 Guardian Respirator Adaptor and publish additional compatibility information as it becomes available. Filter Insert: Once the CV-19 Guardian Respirator Adaptor is inserted into the compatible snorkel mask, a filter insert cut from a commonly available material that effectively captures airborne particles is placed on the sealing surface of the adaptor and secured in place using a compatible lid. The attached PDF file provides instructions for properly making and using filter inserts, along with URL links for commonly available materials that provide effective protection against airborne particles. One example material with good breathability and >99% filtration efficiency of airborne particles of interest is two layers of ADO Pro Pac fabric, which is commonly used to capture particulate from blown insulation (https://www.homedepot.com/p/ADO-Products-10-2-ft-x-375-ft-Pro-Pac-Insulation-Fabric-ICPP122/302709283). As configured, most standard snorkel masks such as the DIVELUX mask allow the wearer to breathe filtered air in through the CV-19 Guardian Respirator and filter insert, and exhale unfiltered air through a vent valve in the front of the mask. This is equivalent to an N95 mask with an exhaust valve, which protects only the person wearing the mask, but not those in close proximity from any airborne particles. Wide Mouth Lid: For maximum compatibility and ease of use for the general public, the diameter and threading of the CV-19 Guardian Respirator Adaptor are the same as that of a wide mouth mason jar. Any standard wide mouth mason jar lid ring (for canning) will fit the adaptor and function as intended (see photos). Compatible lids with sprouting or straining inserts provide good structural protection for the filter insert. One example lid of this type is the Original Speed Strainer Lid(R), https://www.unboundfarm.com/The-Original-Speed-Strainer-Lid_p_12.html. It is not recommended to cut a hole in a single-piece mason jar lid as the sharp edges could damage and compromise the integrity of the filter insert. Details: For additional technical details, refer to the attached photos and PDF file. 3D Print Settings: * Printer used for prototyping: Prusa Mk3 * Rafts: No * Supports: None * Resolution: 0.2 mm * Infill: 20% * Filament - Hatchbox PLA, WhitePTEG or PLA are suitable. In absence of these, other materials should be acceptable as well. ABS tends to shrink after production; a prototype made from this works acceptably, but the shrinkage could result in an inferior seal at the interface or require adjustment. Multi-Jet Fusion (MJF) is expected to be an ideal process for commercial production of this part due to the durability of the resulting parts and demonstrated ability to withstand autoclave disinfection.

Download Model from grabcad

With this file you will be able to print CV-19 Guardian Respirator Adaptor with your 3D printer. Click on the button and save the file on your computer to work, edit or customize your design. You can also find more 3D designs for printers on CV-19 Guardian Respirator Adaptor.