mpa 930 review 3d models
18127 3d models found related to mpa 930 review.grabcad
The refined roboarm now features "Adaptive Mesh Refinement" at high settings. ...It weighs 23.9 kg, withstanding a max stress of 73.26 MPa and boasting a safety factor of 3.39. ...Maximum displacement is 1.472 mm.
grabcad
The calculated mass is 29.696 kg, while the maximum stress according to von Mises equals 81.02 MPa. ...The maximum displacement found is 1.847 mm, and the factor of safety (FOS) reaches a maximum value of 3.06.
grabcad
The results demonstrate a maximum von Misses stress of 82.31 MPa, displacement of 1.8mm, factor of safety at 3.07, applied gravity of 9.81 m/sq s and a total mass of 49.404 kg.
grabcad
Pumping station NEE-5.0I40T1 maximum pressure 70 MPa, flow 5 liters / min, tank 40 liters, asynchronous motor AIR 132 S4 UZ 7.5 kW 1440 r-min. ...3d model.
grabcad
The minimum safety factor is calculated to be 3.01, while the maximum displacement measured was 1.29mm. ...The maximum stress experienced by the component was 82.50 MPa, and its total mass weighs in at 38.05 kg.
grabcad
The finalized Autodesk robot arm exhibits the complete Adaptive Mesh Refinement feature. ...It weighs 20.4 units, has a maximum stress of 79.9 MPa, boasts a safety factor of 3.11, and its maximum displacement is 1.643 mm.
grabcad
The calculated weight is 28.08 kg, and the maximum stress (Von Mises) is 73.14 MPa. ...Additionally, the maximum displacement amounts to 0.4405 mm, and the minimum factor of safety is 3.39.
grabcad
The outcome indicates a weight of 25.35 kg, with a maximum Von Mises stress of 72.6 MPa. ...Additionally, the maximum displacement is recorded at 0.3114 mm and the minimum factor of safety is calculated as 3.42.
grabcad
The calculated mass is 33.049 kg, while the maximum stress according to von Mises theory is 82.41 MPa. ...The structure's maximum displacement measured was 1.676 mm and the factor of safety achieved is 3.01.
grabcad
... kg when made from suggested materials. Simulation results include: - Case P1: Displacement - 9mm; Huber Stress (VM) - 352 MPa - Case P2: Displacement - 2.5mm; Huber Stress (VM) - 296 MPa - Case P3: Displacement - 2.5mm; Huber Stress (VM) - 354 MPa
grabcad
The program CAESS ProTop's topology optimization has been optimized with regard to brackets, resulting in a maximum stress of 30.19 MPa, a mass of 44 grams, and a volume of 0.34 dm^3.
grabcad
The weight is 50 kg, and the displacement of P1 measures at 22 mm. ...Stress screenshots indicate stress levels above 100 MPa. ...Once I learn how to reverse the pressure vector on Simscale simulation, further details will be provided.
grabcad
The inlet/outlet bore has a radius of 0.375 inches, and the pressure is 0.3 MPa. ...The capacity is 10 liters per minute, while it spins at 350 rotations per minute.
grabcad
The results reveal a weight of 35.26 kg, a maximum Von Mises stress of 47.68 MPa, a peak displacement measurement of 0.2166 mm, and a minimum factor of safety at 5.21.
grabcad
The calculated weight is 50.42 Kg. ...The maximum stress, as per Von Mises, is 46.86 MPa. The maximum displacement recorded is 0.2793 mm. ...Finally, the minimum Factor of Safety (FOS) stands at 4.417.
grabcad
The safety factor is 3.09, with a stress level of 80.45 MPa. The displacement measures at 1.166 millimeters and the overall mass amounts to 31.965 kilograms. ...The material used in this case is sheet metal.
grabcad
Key performance metrics include: Load Case 1 with von Mises stress maxing out at 550 MPa (79.7 ksi) and maximum displacement under sum stress (usum) of 0.33 mm; Load Case 2 with a von Mises stress of 588 MPa (85.3 ksi) and usum max of 0.7 mm; Load...
sketchfab
Residential Ground Floor Construction - Constructed Area = 117.00 square meters Concrete Frame Structure Design: 13 cm prestressed slab; FCK used of 25 MPa. ...Frame structure plus hydraulic plumbing/sanitary installations + compatible electrical...
grabcad
For situations where lateral clamping is necessary, utilize a force clamp of 22 kN. ...To release the clamp, apply an unclamping force of 10.2 kN. The stroke length is 20 mm, and the maximum operating pressure is 40 MPa.
grabcad
Estrutura em aço especial STRENX 700 Mpa• Perfis hexagonais• Comprimento fechado : 2000 mm• Comprimento aberto : 3500 mm• 11 (onze) posições de ajuste a cada 150 mm• Pintura eletrostática• Pinos e contra pinos zincados• Peso próprio : 60 kg
grabcad
In load case 2, with a horizontal force of 8500 lbs, the maximum Von Mises stress was 917 MPa (133 ksi), and the safety factor was 1. Load case 3 involved a 9500 lb force at a 42° angle from vertical; the Von Mises stress peaked at 751 MPa (108.9...
grabcad
In this unique creation, I express my individuality. ...Nonetheless, I wonder if a pressure gauge of 175 MPa is truly necessary; however, it's my choice in the end.
grabcad
The product has a minimal volume and boasts an impressive maximum moment of inertia. ...It weighs only 0.041 pounds in total. Under stress, it can withstand up to 26 MPa without breaking.
grabcad
Pumping station NEE-5.0I40T1 maximum pressure 70 MPa, flow 5 liters / min, tank 40 liters, asynchronous motor AIR 132 S4 UZ 7.5 kW 1440 r-min. ...3d model.
grabcad
The outcomes indicate that various types of stress do not reveal significant differences in total deformation, but maximum stress rises by 0.6 MPa from the initial 2 MPa. This warrants further assessment. Furthermore, the directional deformation's...
grabcad
The new test yielded a reduced mass of 31.293 kg, an increased maximum stress (von Misses) of 80.51 MPa, a greater maximum displacement of 1.604 mm, and a slightly lower factor of safety (FOS) of 3.08 in comparison to the original test that showed a...
3docean
... content by clicking on our name. If you can let us know your opinion by reviewing and rating our product, we will take it into consideration for future work, making our job better and more in line with your interests. ... Thanks for your time.