With everything put together, we get a pretty decent standard deviation of 0.002693 mm without moving X and Y as seen in this [Youtube movie](https://www.youtube.com/watch?v=1wUFTY2nHnQ) and the `M48 S1 P20 V4` test results in a decent: ``` Mean:...
thingiverse
Maybe start with Bilinear and if everything works check out UBLMesh Validation, **#define G26_MESH_VALIDATION**, enable to give you a good check if your leveling works!use M48 to check the accuracy of your probe, really handy to check the quality of...
thingiverse
Test for 50 repeat cycle M48 P50 X100 Y100 V2 E Recv: 50 of 50: z: -0.013 Recv: Finished! Recv: Mean: -0.002348 Min: -0.015 Max: 0.009 Range: <b>0.025</b> Recv: Standard Deviation: <b>0.006550</b> Works well with cold and hot bed, hot nozzle. Need...
thingiverse
upload My modified MKS firmware for mks robin nano (fork mks v2.0.2): https://github.com/ochkariky/MKS-Robin-Nano-Firmware_compile (add More menu, M48, add UBL support in autolevel menu, increase length name in Print menu.) Resolves the issue of a...
thingiverse
Wiring universal and Firmware changes: - Please follow the steps described in the official Precision Piezo manual and the RepRap Wiki https://docs.wixstatic.com/ugd/e08222_11eeb2b6951b44acaacbde4eb72ad72e.pdf...
prusaprinters
It also incorporates some random movement and does the entire test with the bed at 60c and Nozzle at 200c to replicate common printing conditions. The closer in value your readings are the more consistent your probe is and that eliminates one cause...
thingiverse
- M48 P10 X100 Y100 V2. * S_CURVE_ACCELERATION is activated. This gives a very slight curve to acceleration. * ENABLE_LEVELING_FADE_HEIGHT is activated. M420 Z6 send this and M500 - Leveling fade Z height - it means your bed leveling data is faded...
thingiverse
You can also enable Z_MIN_PROBE_REPEATABILITY_TEST in the firmware and use M48 L10 P8 V4 to let it test repeatability at the same point with a lot of fake movement in between probes. There are occasions where the sensor after power on gives an...
thingiverse
I ran an M48 repeatability test with these results. Mean: 4.902201 Min: 4.901 Max: 4.904 Range 0.004 Std Dev 0.001239 EVERY PRINTER IS CONFIGURED DIFFERENT AND I AM NOT GOING TO TROUBLESHOOT EVERYBODY’S SETUP NOR AM I RESPONSIBLE for...
prusaprinters
M48 Repeatability Test for this hotend mount: Mean: 0.026750 Min: 0.022 Max: 0.030 Range: 0.008 Standard Deviation: 0.001953 One giant "Thank you" to David Ramiro who assisted me numerous times concerning the software implementation of the Z-probe on...
thingiverse
- removed "Disarm" button from the manual leveling menu (there was no practical use of it there) ([PR #2825](https://github.com/bigtreetech/BIGTREETECH-TouchScreenFirmware/pull/2825)) - there's no submenu there anymore, "Distance" and "Shim" buttons...
prusaprinters
Optional hole for M3 screw to secure. List and description of non-3D printed parts: (numbers correspond to those labeled in the montage photos)Energy rejection: 2 inch sub-aperture ERF (Optolong UV/IR on KG3 +/- Baader 35nm H-alpha) or – in theory –...
cults3d
Marlin's M48 probe repeatability test shows a standard deviation over 10 probes of 0.009014mm. So its very reproducible. Try this test with your old probe before trying this one. Please be aware with this sensor in its current build, there is no...
thingiverse
The proper support (STL file) is provided in the zip file * enabled "Probe Repeatability Test" to use M48 gcode * enabled "ABL Bilinear" * enabled "Restore Leveling After G28" to restore saved leveling data after every G28 gcode execution * enabled...
thingiverse
The proper support (STL file) is provided in the zip file - enabled "Probe Repeatability Test" to use M48 gcode - enabled "ABL Bilinear" - enabled "Restore Leveling After G28" to restore saved leveling data after every G28 gcode execution - enabled...